1

MFC700 series features

MFC700 series features

European Union technology international brand China manufacturing world advanced

The MFC700 series of inverters includes MFC710 classic, MFC720 heavy duty universal, MFC760 special heavy duty and MFC780 energy feedback, which can provide targeted solutions according to the requirements of different industries and use environments.

Product features:

1, DTC-SVM direct torque control space vector modulation, with encoder, 0HZ can output 200% torque. Without encoder, 0.5HZ can output 200% torque;

2, the combination of high-speed DSP processor and high-performance motor identification algorithm, sensorless control accuracy, dynamic response speed, small torque ripple;

3, provide over voltage, over current, over heat, over temperature, short circuit and leakage protection, protection measures perfect;

4, built-in PLC and industry-specific controller, simple and convenient operation control;

5. Built-in EMC filter, electromagnetic radiation value is at least 14dB lower than the national standard, and some frequency bands are 40dB lower;

6, super heavy special inverter, 15Kw above the standard built-in DC reactor, input harmonic is small, strong reliability;

7, the four-quadrant energy feedback machine can feedback 100% of the energy generated by the motor brake back to the grid, the harmonic content of the feedback current is less than 3%, and the power factor is more than 0.99.

MFC700 Full range of product specifications

Model description:

MFC7XX (Product Range) XX (Type structure) XXXX (rated current) X(voltage classes) X(brake unit)
10:classical type 01:wall-mounted 0011:11A 3:400V 0:nonbraking
20:Heavy duty universal type     5:500V 1:braking
60:Super heavy duty dedicated     6:690V  
80:Energy feedback form

Power grade 400V:

model Constant torque load Pump and fan loads Overload 60 seconds of current every 10 minutes (A)
rated power (kW) rated output current (A) rated power ( kW ) rated output current (A)
MFC7XX-01-0003-3-X 0.75 2.5 1.1 3.5 3.75
MFC7XX -XX-0004-3-X 1.1 3.5 1.5 4 5.25
MFC7XX -XX-0005-3-X 1.5 4 2.2 5.5 6
MFC7XX-01-0007-3-X 2.2 5.5 3 7.8 8.3
MFC7XX -XX-0010-3-X 3 7.8 4 10 11.7
MFC7XX -XX-0012-3-X 4 10 5.5 12 15.8
MFC7XX -XX-0018-3-X 5.5 12 7.5 18 18
MFC7XX -XX-0024-3-X 7.5 18 11 24 27
MFC7XX -XX-0030-3-X 11 24 15 30 36
MFC7XX -XX-0039-3-X 15 30 18.5 39 45
MFC7XX -XX-0045-3-X 18.5 39 22 45 60
MFC7XX -XX-0060-3-X 22 45 30 60 68
MFC7XX -XX-0075-3-X 30 60 37 75 90
MFC7XX -XX-0090-3-X 37 75 45 90 112
MFC7XX -XX-0110-3-X 45 90 55 110 135
MFC7XX -XX-0150-3-X 55 110 75 150 165
MFC7XX -XX-0180-3-X 75 150 90 180 225
MFC7XX -XX-0210-3-X 90 180 110 210 270
MFC7XX -XX-0250-3-X 110 210 132 250 315
MFC7XX -XX-0310-3-X 132 250 160 310 375
MFC7XX -XX-0380-3-X 160 310 200 380 465
MFC7XX -XX-0460-3-X 200 380 250 460 570
MFC7XX -XX-0570-3-X 250 460 315 570 690
MFC7XX -XX-0680-3-X 315 570 355 680 850
MFC7XX -XX-0730-3-X 355 650 400 730 940
MFC7XX -XX-0820-3-X 400 730 450 820 1100
MFC7XX -XX-0910-3-X 450 820 500 910 1190
MFC7XX -XX-1020-3-X 500 910 560 1020 1365

Power grade 500V:

model Constant torque load Pump and fan loads Overload 60 seconds of current every 10 minutes(A)
rated power (kW) rated output current (A) rated power (kW) rated output current (A)
MFC7XX -XX-0032-5-X 15 24 18.5 32 36
MFC7XX -XX-0037-5-X 18.5 32 22 37 48
MFC7XX -XX-0050-5-X 22 37 30 50 56
MFC7XX -XX-0060-5-X 30 50 37 60 75
MFC7XX -XX-0072-5-X 37 60 45 72 90
MFC7XX -XX-0090-5-X 45 72 55 90 108
MFC7XX -XX-0120-5-X 55 90 75 120 135
MFC7XX -XX-0150-5-X 75 120 90 150 180
MFC7XX -XX-0180-5-X 90 150 110 180 225
MFC7XX -XX-0200-5-X 100 180 132 200 270
MFC7XX -XX-0250-5-X 132 200 160 250 300
MFC7XX -XX-0300-5-X 160 250 180 300 375
MFC7XX -XX-0380-5-X 200 300 250 380 450
MFC7XX -XX-0475-5-X 250 380 315 475 570
MFC7XX -XX-0520-5-X 315 475 355 520 713
MFC7XX -XX-0584-5-X 355 520 400 584 780
MFC7XX -XX-0656-5-X 400 584 450 656 876
MFC7XX -XX-0728-5-X 450 656 500 728 984
MFC7XX -XX-0816-5-X 500 728 560 816 1092
MFC7XX -XX-0900-5-X 560 816 630 900 1224

Power grade 690V:

model Constant torque load Pump and fan loads Overload 60 seconds of current every 10 minutes(A)
rated power (kW) rated output current (A)(A) rated power (kW) rated output current (A)
MFC7XX -XX-0104-6-X 75 87 90 104 130
MFC7XX -XX-0121-6-X 90 104 110 121 156
MFC7XX -XX-0144-6-X 110 121 132 144 182
MFC7XX -XX-0179-6-X 132 144 160 179 217
MFC7XX -XX-0219-6-X 160 179 180 219 268
MFC7XX -XX-0266-6-X 200 219 250 266 329
MFC7XX -XX-0329-6-X 250 266 315 329 398
MFC7XX -XX-0393-6-X 315 329 355 393 491
MFC7XX -XX-0420-6-X 355 375 400 420 530
MFC7XX -XX-0470-6-X 450 470 450 470 540
MFC7XX -XX-0500-6-X 500 500 500 500 550
MFC7XX -XX-0560-6-X 560 560 560 560 615
MFC7XX -XX-0650-6-X 630 650 630 650 715
MFC7XX -XX-0800-6-X 800 800 800 800 920

product data

Power supply Input voltage Uin Three-phase voltage: 380V -15% ~ +10%
Frequency 45 ~ 66Hz
Output Output voltage 0 ~ Uin[V]
Output frequency 0.0 ~ 400.0Hz
Frequency accuracy 0.01Hz (vector)
Control system Modulation SVPWM(Space Vector Pulse Width Modulation)
Working mode U/f linear scalar, U/f square scalar
Sensorless DTC-SVM(Direct Torque Control-Space Vector Modulation)
DTC-SVM(Direct Torque Control-Space Vector Modulation) with sensor at rotor position
Switching frequency 2 ~ 15kHz, random carrier modulation
Speed setting Analog input, operating panel, point potentiometer,PID regulator, RS232 or RS485 communication, PLC module, other Settings (advanced programming).
Accuracy: 0.1% for analog inputs; For the operating panel and RS, 0.1Hz/1rpm
I/O control Analog input 3 analog inputs:
AI0: Voltage mode 0(2) ~ 10V, input resistance ≥200k
AI1,AI2: Voltage mode 0(2) ~ 10V, input resistance ≥100k;
Current mode 0(4) ~ 20mA, input resistance =250
Set operating mode and polarity with parameters and jump pins
Accuracy: 0.5%
Digital input 6 channels Independent input 0/(15 ~ 24)V. Input resistance ≥3 k
Analog output 2 analog outputs: 0(2) ~ 10V/0(4) ~ 20mA- via parameter and skip pin Settings
Accuracy: 0.5%
Digital output Programmable digital output
3 relays output K1,K2,K3, open capacity: AC 250V/1A, DC 30V/1A;
1 collector open circuit output 100mA/24V
Communication Connector RS232,RS485 with photoelectric isolation
Communication protocol MODBUS RTU. Function 3 (read register); Function 6 (Write register)
Transmission speed 1200,2400,9600 or 19200bit/s
Application Remote control module work and edit all inverter parameters
Special features PID regulator Select reference and feedback signal sources, reverse the polarity of the deviated signal, limit the output value, sleep function
PLC controller can control the operation of the entire inverter, start/stop the system, rotation direction and frequency, and can control any complex process without connecting to an external PLC controller;
48 general function modules, 43 functions: simple logic and arithmetic module, 8-state sequence generator module, two 8-input multiplexers, curve construction unit;
Maximum execution time of PLC program: 10ms
Pump Unit controller can cascade up to 5 pumps;
Control by PID regulator or direct manual control;
Each pump can be independently edited to operate from the inverter or from the power supply network;
Can stop the pump;
Pump can be replaced automatically after a preset period of time
Special features Factory macro There are nine sets of factory macros:
– Local: Controls from the operation panel
– Remote: controlled by digital or analog input
– Local/Remote: Select between local and remote
-PID: Adjusts the rotational speed using the PID controller
– Point potentiometer: controlled by an “increase/decrease” signal from a digital input
– Constant frequency: Select different constant frequencies through digital input
– Torque regulation: Set torque by signal from digital input, vector control
– Pump unit: Control pump unit
– Winding calculator: Set torque via winding calculator, vector control
Additional functions for the operation panel Define a user reference unit for observing process variables – select the unit, precision and data source (for example, from a PLC controller)
Define user reference units for changing process variables – select units and precision
LCD Contrast adjustment
Protection Short Circuit protection Output short Circuit protection
Overcurrent protection Instantaneous value 3.5In; Valid Value 2.5In
Overvoltage protection AC 1.47Uin (Uin=380V); Dc 750V
Undervoltage
Thermal protection Heat sensor for radiator. For 15kW and below, 85℃; For others, 75℃
Motor Thermal protection I2t limit, motor heat sensor
Monitor the connection of the operation panel Set the allowable communication loss time
Monitor RS connection Set the allowable communication loss time
Monitor analog input In modes 2-10V and 4-20mA, the monitoring analog input value is not too small.
Monitoring load symmetry For example, interrupt a phase
Insufficient load Running protection without any load
Stall Motor stall protection